Dorokhov Victor
WEP08
The project of Kirkpatrick – Baez focusing system for beam diagnostics on the SKIF
256
The Siberian Ring Radiation Source (SKIF) is an upcoming 4th-generation SR source under construction in Novosibirsk, Russia. The designed beam emittance for SKIF is 75 pm-rad, which corresponds to a beam size of 6 micrometers at the observation point within the dipole magnet. The transverse beam dimensions are essential parameters for tuning and reliable operation of the facility. The SKIF diagnostic suite includes a double-slit interferometer operating in the ultraviolet region of the spectrum. This device's spatial resolution should be sufficient to measure the radial size of the beam to an accuracy of 10 percent. These diagnostics will be used during the commissioning of SKIF and afterwards. Although an additional source of information on beam dimensions and dynamics would be desirable for assurance, taking into account the record designed value of beam emittance. The application of X-ray optics and the Kirkpatrick-Baez focusing system seem to be the most suitable options. The article discusses the project of this system, which will acquire X-rays from a SKIF dipole magnet. Simulations of the heat load on the mirrors, means of compensation of thermo-induced surface distortion (thermo-bump) and the spatial resolution of the KB system are described. The choice of scintillator screens, expected temporal resolution, and sensitivity of the diagnostics are discussed as well.
  • O. Meshkov, D. Reshetov, V. Dorokhov
    Budker Institute of Nuclear Physics
  • E. Glushkov, I. Malyshev
    Institute of Applied Physics
Paper: WEP08
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-WEP08
About:  Received: 04 Sep 2024 — Revised: 09 Sep 2024 — Accepted: 10 Sep 2024 — Issue date: 17 Sep 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
WEP13
The study of beam dynamics at the VEPP-2000 collider using a gated camera
268
The Nanogate-38 gated camera with a temporal resolution of 60 nanoseconds was used to measure the transverse beam dimensions in the BEP booster and the VEPP-2000 electron-positron collider. The camera was used in combination with a double-slit interferometer to measure the vertical beam size and with projection optics to construct a transverse beam profile in single-turn mode. Some beam characteristics were measured, such as decoherence time, radiation damping time and fast attenuation time. The purpose of these experiments was to investigate the possibility of using this camera to measure the transverse dimensions of the beam and its emittance, as well as to conduct experiments on accelerator physics at the SKIF synchrotron radiation source.
  • M. Timoshenko, V. Dorokhov
    Budker Institute of Nuclear Physics
  • O. Meshkov, S. Sherstyuk, V. Boyarkina
    Budker Institute of Nuclear Physics & Novosibirsk State University
Paper: WEP13
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-WEP13
About:  Received: 05 Sep 2024 — Revised: 09 Sep 2024 — Accepted: 10 Sep 2024 — Issue date: 17 Sep 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote