Mohammadi Alamouti Samira
TUP07
Stripline design for tune measurement in the ILSF Storage Ring
39
The Iranian Light Source Facility Storage Ring is under design with a 528 m circumference and will store the electron bunches with 3 GeV energy to produce high-flux radiation that ranges from infrared to hard X-rays. Two Striplines are planned to be installed in the ILSF storage ring for beam tune measurement. The first one will be used for exciting the beam and the other for horizontal and vertical beam position measurements. In this paper, the design of the striplines for the ILSF storage ring is investigated. Each stripline is matched with 50Ω and has 4 strips (electrodes) that are placed at 45 degrees to the beam axis, the best geometry is achieved and optimized by CST Microwave Studio simulation.
  • S. Mohammadi Alamouti, A. Danaeifard, N. Khosravi, Z. Rezaei
    Iranian Light Source Facility
Paper: TUP07
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-TUP07
About:  Received: 05 Sep 2024 — Revised: 11 Sep 2024 — Accepted: 12 Sep 2024 — Issue date: 17 Sep 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
TUP08
Design of button beam position monitor for the ILSF booster
43
The Iranian Light Source Facility Booster is under design with a 504 m circumference and will accelerate the electron bunches from 150 MeV to 3 GeV. the 50 button-type beam position monitors (BPMs) are considered the non-destructive tools to measure the beam position in the ILSF booster. In this paper, the design of the BPM for the ILSF booster is studied. The BPM blocks have 4 buttons (electrodes) that are placed at 45 degrees to the beam axis. to choose the best geometry, The BPMs with different button diameters and gaps are simulated by the CST Microwave Studio and BpmLab.
  • S. Mohammadi Alamouti, A. Danaeifard, N. Khosravi, Z. Rezaei
    Iranian Light Source Facility
Paper: TUP08
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-TUP08
About:  Received: 05 Sep 2024 — Revised: 11 Sep 2024 — Accepted: 11 Sep 2024 — Issue date: 17 Sep 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
WEP58
Beam diagnostics control system upgrade of IPM LINAC
399
A series of upgrades has now begun to industrialize the applications of the experimental IPM electron LINAC. This includes upgrading the control system of the diagnostics tools and adding new tools and equipment to the system as well. The aim is to build an integrated control system to collect and manage all diagnostics signals. This will allow us to continuously monitor and archive all of the beam parameters for LINAC performance analysis and improvement. It is hence decided to migrate from LabVIEW to an EPICS-based control system which has many advantages in this regard. In the meantime, it is also required to employ more modern equipment with better control interfaces and add some extra diagnostics tools to the system as well. So during this upgrade, most of the job would be developing new control interfaces and high-level applications accordingly. In this paper, after a brief summary of the current diagnostics tools and our motivation for this upgrade, the scheme of the new control system and how different parts are integrated to the EPICS framework will be described.
  • P. Navidpour, S. Mohammadi Alamouti, Z. Rezaei
    Iranian Light Source Facility
Paper: WEP58
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-WEP58
About:  Received: 04 Sep 2024 — Revised: 10 Sep 2024 — Accepted: 10 Sep 2024 — Issue date: 17 Sep 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
WEP59
Beam profile monitoring using incoherent Cherenkov Diffraction Radiation and scintillating screens at ILSF
403
The Iranian Light Source Facility (ILSF) plays a crucial role in advancing accelerator science and applications. In this study, we explore innovative techniques for precise beam profile monitoring, focusing on two complementary methods: Incoherent Cherenkov Diffraction Radiation (ChDR) and scintillating screens. Incoherent ChDR occurs when a charged particle passes through a dielectric medium with a velocity exceeding the phase velocity of light in that medium. This phenomenon leads to the emission of electromagnetic radiation in the form of a cone. Our investigation focuses on incoherent ChDR as a powerful tool for beam position diagnostics. By analyzing the angular distribution of ChDR photons, we extract valuable information about the transverse position of the electron bunch. Our simulations demonstrate the feasibility of ChDR-based diagnostics at ILSF. We discuss optimal radiator materials, geometries, and detection strategies. in addition, We also present our findings on scintillating screen calibration, spatial resolution, and dynamic range. We believe that our research significantly contributes to the development of robust and efficient beam diagnostics at the storage ring of ILSF. By investigating Cherenkov Diffraction Radiation (ChDR) and utilizing radiation from scintillating screens, we enhance accelerator performance and facilitate future experiments.
  • Z. Rezaei, S. Mohammadi Alamouti, N. Khodabakhshi, P. Navidpour, S. Ahmadiannamin
    Iranian Light Source Facility
  • Z. Pouyanrad
    Amirkabir University of Technology
  • K. Noori
    Iran University of Science and Technology
Paper: WEP59
DOI: reference for this paper: 10.18429/JACoW-IBIC2024-WEP59
About:  Received: 07 Sep 2024 — Revised: 09 Sep 2024 — Accepted: 09 Sep 2024 — Issue date: 17 Sep 2024
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote
THP17
Study of gas bremsstrahlung for 3 GeV electron storage ring using FLUKA Monte Carlo code
The Iranian Light Source Facility, ILSF, is under design as a 3 GeV synchrotron light source. The storage ring of ILSF with a 528 m circumference and NEG-coated vacuum chamber is used to achieve the desired vacuum level. In this paper, the monitoring system for gas bremsstrahlung radiation from the storage ring is studied. Gas bremsstrahlung is produced when the stored electron beam interacts with residual gas molecules in a storage ring vacuum chamber. The simplified geometry of the gas bremsstrahlung detector consists of a scintillator, an aluminum holder, and a lead sheet. This geometry is used in the FLUKA simulation package to study gas bremsstrahlung production in SR and its interaction with the detector.
  • S. Mohammadi Alamouti, E. Salimi, Z. Rezaei
    Iranian Light Source Facility
  • I. Moraes
    Centro Nacional de Pesquisa em Energia e Materiais
Cite: reference for this paper using: BibTeX, LaTeX, Text/Word, RIS, EndNote